The leak status of the chamber filter press can be a common problem for many users. It is necessary to explain the reasons for the leakage of the chamber filter press and the treatment methods. This can help widely used units deal with problems in a timely manner and increase production capacity.

chamber filter press

1. Leakage due to insufficient compaction

If some of the filter plates of the chamber filter press are found to be leaking, there is a problem that the pressing force cannot be formed under normal conditions. The pressure is generally: plastic filter plate 15 ~ 20Mpa. In the case of insufficient pressure, we can gradually increase the pressure, but be careful not to exceed the additional pressure. Proper pressure ensures a leak-free service life of the chamber filter press. We activate the Compression button when we add the compression force. At this point, the motor rolls forward and the femoral oil pump starts to work. After pressing the filter plate, adjust the high-pressure relief valve clockwise and check the pressure on the pressure gauge. Adjust the pressure to the proper application range before starting work.

2. There are impurities on the sealing surface of the chamber filter press filter plate

Due to the debris, the filter plate of the chamber filter press will be squeezed, but the gap formed by the debris will create a problem of leakage. Handling such doubts is relatively straightforward. We just need to pay attention to the debris on the sealing face. Before each press, make sure there is no debris between the chamber filter press plates.

3. Problems caused by uneven folding of filter cloth and irregular arrangement of filter plates

Wrinkles and unevenness in the filter cloth can also cause leaks in the chamber filter press. Therefore, we have to question whether or not the filter cloth is formed by a plate and frame filter press. Since the filter cloth is not flat, the filter plate is not squeezed tightly, so there will be leaks. If this is found, the non-woven fabric must be sewn and the filter cloth smooth. Improper placement of filter plates can also cause leaks. Generally speaking, the maximum displacement of the filter plate should not exceed 5 mm, otherwise, it will only show the state of leakage. If this is found, filter plates can be arranged regularly.

In addition to geotextiles, when the feed pressure of the chamber filter press is too high, it also shows leakage. As the feed pressure is too high, it will show varying degrees of backpressure. Pressure must be controlled with additional pressure. In addition, the flow rate of the feed pump is too large, and there will be doubts. The solution to such doubts is to adjust the feed pump valve, install the oil return line and open the oil return valve.

The above is the reason for the leak of the chamber filter press introduced to you, I hope it will be helpful to you. As a chamber filter press enterprise, Kintep produces products with stable performance. If you want to know more about chamber filter press, then come and pay attention to our website.