Installation Notes


1, turbulence tower spray equipment body, pump, fan recommended to install on the concrete basis, the equipment is secured by expansion bolts.
2, if the equipment is installed and working outdoors, winter temperature should be considered when the bottom of the equipment tank for antifreeze treatment.
3, the equipment water tank has a level mark, before use must be in accordance with the level mark into the absorption fluid. During use, care should be taken to replenish the absorbent fluid in a timely manner.
4, when using should first open the circulating pump, and then turn on the blower, stop the blower should first stop the blower 1-2 minutes later, then stop the circulating pump.
5, according to the use of regular inspection of the equipment water tank liquid depth and exhaust gas purification degree, should be in accordance with the operation of the equipment timely replacement of the bottom of the pool of absorption liquid.
6, this equipment one and a half to two years should do an overhaul, check the disk spray tube and filler filling situation, and clean it. Structure Description
The equipment is divided into mono-towers and twin towers.

A circular tower is used and joined in flange segments. Specifically by the storage tank, tower, air intake section, spray layer, filler layer, cyclone defog layer, inspection window, air outlet and so on. Equipment scope Refineries,
rubber factories, leather factories, printing plants, chemical plants, Chinese and Western medicine plants, metal foundries, plastic recycling plants, spray solvents, food processing plants, meat processing plants, slaughterhouses, poultry feed farms, paper mills, sewage treatment plants, waste transfer stations and other organic and inorganic waste gas purification treatment.

Performance specification parameters table

 

the device model size
(mm)
design air
volume (m3/h)
Fan Power
(KW)
Full
pressure (Pa)
Circulating
fluid pump (N-KW)
Circulating
fluid pump (Q-m3/h)
Circulating
fluid pump (H-m)
BHF/650 Φ650×H3000 1500 1.1 290 1.1 6.3 15-20
BHF/800 Φ800×H3100 3000 1.1 390 1.5 12.5 15-20
BHF/1000 Φ1000×H3600 6000 2.2 490 2.2 15 15-20
BHF/1200 Φ1200×H3900 7500 4.0 800 4 25 20-25
BHF/1400 Φ1400×H4200 10000 5.5 1200 4 30 20-25
BHF/1600 Φ1600×H4200 15000 7.5 800 5.5 35 20-25
BHF/2000 Φ2000×H4500 20000 11 1000 11 60 25-30
BHF/2400 Φ2400×H4800 24000 15 1000 11 80 25-30
BHF/3000 Φ3000×H4800 30000 18.5 600 15 100 25-30
BHF/3500 Φ3500×H5500 35000 30 1000 15 100 25-30
NaOH liquid concentration 2-6% suggestion 5%  
operating temperature 0-50℃ suggestion 25℃  
the depth of the filter layer 400-600mm standard 500mm  
cyanide-containing exhaust gas design flow rates 0.3-0.6m/s residence time 8-10m/s single-stage purification efficiency 95-97% 25-32℃
contains chromium exhaust gas design flow rates 0.3-0.6m/s residence time 9-12m/s single-stage purification efficiency 92-95% 25-32℃
contains ammonia exhaust gas design flow rates 0.3-0.6m/s residence time 8-10m/s single-stage purification efficiency 95-98% 25-32℃
contains acid mist exhaust gas design flow rates 1m/s residence time 5-6m/s single-stage purification efficiency 95-97% 25-32℃
CONTAINS NOX EXHAUST GAS design flow rates 0.3-0.6m/s residence time 8-10m/s single-stage purification efficiency 95-96% 25-32℃
Contains H2s, exhaust gas design flow rates 0.3-0.6m/s residence time 8-10m/s single-stage purification efficiency 92-97% 25-32℃
the device material Q235 PLUS LINED FRP, Q235 PLUS LINED PO, PP, FRP, SS304, SS316L
The above technical description is provided by (Shenzhen Xicheng Environmental Protection Technology Co., Ltd.).